CheckPFAS

ZIP Code 28452

High Risk
High Risk PFAS Risk Level

PFAS above EPA limits detected

2 compounds exceed EPA Maximum Contaminant Levels in water serving this ZIP code. Standard pitcher filters like Brita do not remove PFAS. See filter recommendations below.

9
PFAS Detected
2
Above EPA Limits
1
Water System
310%
Highest % of MCL

Compounds Exceeding EPA Limits

PFOS Exceeds EPA limit
0 ppt MCL: 4 ppt 310% of limit
Detected: 12.40 ppt
PFOA Exceeds EPA limit
0 ppt MCL: 4 ppt 193% of limit
Detected: 7.70 ppt

What this means for you

One or more PFAS compounds were measured above the EPA's enforceable drinking water limit at a utility serving ZIP 28452. The EPA set these limits because long-term exposure at higher concentrations is associated with health effects including immune suppression, thyroid changes, and cancer risk increases. Standard pitcher filters (Brita, PUR) are not certified to remove PFAS. The most reliable at-home options are under-sink reverse osmosis systems or activated carbon block filters with an NSF/ANSI 58 certification specifically listing PFOA/PFOS reduction. Your water utility is required to bring levels into compliance by 2029 — filtering at the tap is the practical interim step if you'd like additional protection now.

BRUNSWICK COUNTY WATER SYSTEM

NC0410045 High Risk
Water Type
Surface Water
PFAS Detected
9
Above MCL
2
State
North Carolina
Data Period
2023–2025

PFAS Test Results

CompoundDetectedvs. EPA LimitEPA LimitStatus
PFOS
Perfluorooctane sulfonic acid
12.40ppt
310% of limit
4 ppt⚠ Exceeds MCL
PFOA
Perfluorooctanoic acid
7.70ppt
193% of limit
4 ppt⚠ Exceeds MCL
HFPO-DA
GenX (Hexafluoropropylene oxide dimer acid)
5.80ppt
58% of limit
10 pptBelow limit
PFHxS
Perfluorohexane sulfonic acid
5.20ppt
52% of limit
10 pptBelow limit
PFPeA
Perfluoropentanoic acid
11.50pptNo federal limitUnregulated
PFHxA
Perfluorohexanoic acid
9.80pptNo federal limitUnregulated
PFBA
Perfluorobutanoic acid
8.50pptNo federal limitUnregulated
PFBS
Perfluorobutane sulfonic acid
7.10pptNo federal limitUnregulated
Show 1 more compound detected at low levels
PFHpAPerfluoroheptanoic acid4.10 pptNo federal limit
About this data
Source
EPA UCMR 5 (Unregulated Contaminant Monitoring Rule, 5th cycle)
Data released
January 2026
Sampling period
January 2023 – December 2025
Systems tested
~10,000 public water systems serving > 25 people
Water system (PWSID)
NC0410045
Detection threshold (MRL)
~1.5–2 ppt — "Not detected" means below this floor, not zero